Preparing PBSA for the Heating Season

8 Steps Before the Christmas Break. 

Tips on how to keep thermal energy waste low through the quietest, coldest weeks of the academic year – with or without automated temperature controls. 

Between late December and mid-January, most purpose-built student accommodation (PBSA) assets empty out at the coldest point of the heating season. Every room heated with nobody in it carries thermal energy waste for up to three weeks, and how much depends on decisions made well before residents leave: The settings, the policies and the handful of checks agreed in November and December. 

Working alongside operators across 13 countries, Utopi sees the same pattern in UK and EU student accommodation. The assets that come through the break with the least thermal energy waste tend to share one approach: Settings and policies are agreed once, with purpose, and the only thing left to manage is drift. The eight steps below come from the heating season playbook the Utopi Impact Team shares with customers. They are split by whether an asset has automated temperature controls, because the work before the break looks quite different in each case. 

PBSA Assets with Automated Temperature Controls 

In a controlled asset, rooms step down by themselves when residents are out. The work before the break is making sure the settings, the exceptions and the resident messaging all support that. 

  1. 1. Confirm settings and close exceptions 

The settings in The Utopi Platform™ already do most of the work, so it is worth checking them against what was agreed at set-up with your Customer Impact Manager. The recommended baseline is a 20°C target temperature, which balances comfort with efficiency, and a 22°C maximum, with boost limited to one to two hours. Above 22°C, rooms tend to overheat. Exceptions are capped at 10% of rooms, and each carries a reason, an end date and sign-off. An exception that runs past the start of the break holds an empty room at a higher temperature for weeks, so the run-up to Christmas is a natural point to end any that no longer have a reason behind them. 

  1. 2. Shorten the occupancy step-down 

The occupancy step-down is the setting with the biggest effect on energy use in a controlled room. Timings carried over from other residential settings are often too long for student accommodation: Students rarely leave their room for more than two hours at a time, so a step-down that waits longer seldom triggers. A first stage to 18°C after an hour catches everyday absences, and a deeper second stage to 14°C does its work over the break. Your Customer Impact Manager can recommend timings for each asset. 

  1. 3. Check rooms after every checkout 

Controls only step a room down when they are left to do so. In one PBSA asset, a room was left heated after checkout through the resident app, holding 29.2°C for a week after the resident had gone and using 248kWh in that time. Switching it off brought the room down to 21.5°C within a day. A quick check after each checkout catches overrides like this before they run through the break. 

  1. 4. Tell residents what the controls do 

Residents who understand the controls tend to get on with them. Where rooms have temperature controls, the message covers using boost rather than turning the heating right up, keeping windows shut while the heating is on, and switching off before going home. Email tends to carry these messages furthest, with 70% of students saying they trust email most and 68% preferring it (Youth Forum #17, The Property Marketing Strategists, October 2026). 

PBSA Assets without Automated Controls 

Without automated controls, heating comes down to people, and the break is when that matters most. The work before the break is finding the heated empty rooms, acting on them, and asking residents to switch off before they leave. 

  1. 5. Find the heated empty rooms 

In The Utopi Platform, the Overview page shows unoccupied spaces by when motion was last detected, and the Utopi Heatmap shows room temperatures building by building. Warm rooms with no motion are the place to start, and a room running several degrees warmer than its neighbours often has an extra heat source. In one example of heating an empty room, Utopi Multisensor™ temperature and motion data showed a space at 28.4°C in March with nobody in it. The site team switched the heating off and the average fell to 17.4°C within a week, an 11°C drop worth an estimated £297 of cost avoidance over a 200-day heating season. Elsewhere, two overheated studios were the warmest spaces in an electrically heated PBSA asset, running at 28.7°C and 32.3°C while empty. Switching the heating off brought them down to 22.9°C and 23.7°C, an estimated £1,440 of cost avoidance over a 200-day heating season. 

  1. 6. Open rogue heater conversations with the temperature 

Heaters that residents bring in sit outside any building controls, so this step applies to controlled assets too. They are a health and safety concern as well as a source of thermal energy waste, and the Rogue Heaters list in The Utopi Platform shows where to look. In one case, the Utopi Heatmap showed a space at 31°C while the rooms beside it sat at 22.5°C. The site team found a heater plugged in and left on full in the empty room, and switching it off cut that space’s energy use by 68% in a day. The same pattern shows up at portfolio level: Across one PBSA portfolio of ten assets, all with automated temperature controls in place, 112 rogue heaters were found and removed in nine of them, an estimated £23,744 of cost avoidance over a 200-day heating season. These conversations tend to go more easily when they open with the room’s temperature. 

  1. 7. Run the list again as residents leave 

Residents leave across the final week of term, so a sweep run too early misses the rooms that empty later. One sweep timed for when most residents have gone, with one person owning the list, keeps it current without adding a recurring task. Warm rooms with no motion go to the top, followed by any space over 24°C. 

  1. 8. Ask residents to switch off before they leave 

Where rooms have no controls, the message is simple: Switch the heater off before you go home. It lands best a week or two before most residents leave, with a reminder closer to move-out. Utopi customers can request a ready-made Christmas Switch-Off pack, with two campaigns matched to the heating in each building, two emails, an A4 poster and a screen video, personalised in about ten minutes. Email customer-impact@utopi.co.uk or get in touch through the Utopi contact page. 

During the Break: Utopi Rated™ Tracks the Drift 

With settings and policies in place, the break itself needs little more than two ten-minute checks, one in each week, looking for any empty room above 24°C in the Heated Unoccupied Spaces and Rogue Heaters lists. Beyond that, Utopi Rated™ tracks thermal energy waste across four measures: Average Indoor Temperature (ideally 20°C or below), Spaces Over 24°C, Heated Unoccupied Spaces and Rogue Heaters (each ideally 0%). The rating is calculated daily from Utopi Multisensor ™ data, and is a proxy for thermal energy waste rather than a meter reading. Asset managers get one rating to watch, and operations teams see which of the four measures has drifted. 

Beyond the Christmas Break 

The Christmas break is the sharpest test of the heating season, but the same habits hold through to 31 March: Settings agreed once, exceptions kept current, and warm empty rooms found early. Treating the run-up to Christmas as a health check on procedures gives each asset a clear starting point for January, and a rating that shows whether thermal energy waste is moving in the right direction. 

Utopi customers can request the heating season playbook and the Christmas Switch-Off pack from their Customer Impact Manager, by emailing customer-impact@utopi.co.uk, or through the contact page. To see how Utopi Rated and The Utopi Platform support heating season planning across your assets, visit utopi.co.uk. 

?> ?>